Manufacturer of Dropout fuse cutout, lightning surge Arrester, DISCONNECTING SWITCH, INSULATOR, WALL BUSING and INSLATING PROTECTION COVEr
email: info@abimat-electric.com        WeChat: 18368780285

PRODUCT LIST:

  • Standardized fuse cutout
  • ABFCO121 fuse cutout
  • ABFCO122 fuse cutout
  • ABFCO123 fuse cutout
  • ABFCO124 fuse cutout
  • ABFCO125 fuse cutout
  • 300A & 400A fuse cutout
  • Load break fuse cutout
  • Wind-resistant fuse cutout
  • Fuse Cutout Fittings – Brass Casting
  • Fuse Cutout Fittings – Stamped parts
  • Fuse Cutout Fittings – Fuse Links
  • Fuse Cutout Fittings – Other Accessories
  • Low voltage surge arrester
  • Distribution surge arrester
  • Polymer surge arrester
  • Anti pollution surge arrester
  • Pillar surge arrester
  • Station surge arrester
  • Capacitive surge arrester
  • Line type surge arrester
  • Dropout surge arrester
  • Arrester disconnection, time, online monitor
  • ABG1 disconnecting switch
  • ABG2 disconnecting switch
  • ABG3 disconnecting switch
  • ABG4 disconnecting switch
  • GW1 disconnecting switch
  • GW4 disconnecting switch
  • GW5 disconnecting switch
  • Low voltage disconnecting switch
  • Suspension insulator
  • Pin insulator
  • Post insulator
  • Cross arm insulator
  • Other insulator
  • Insulator hardware
  • Composite dry wall bushing
  • Porcelain wall bushing

Abimat Electric

  • ADDRESS: Deyu Road 5, Xiangyang Industry District, Yueqing City, Zhejiang Province, China
  • Email: info@abimat-electric.com
  • Wechat: 18368780285
WeChat Abimat Electric

115 kV Disconnect Switch: Essential Component for Transmission System Safety & Maintenance

Operational Principle & Functional Design

In 115 kV high-voltage transmission systems, the disconnect switch (disconnector) fulfills a critical safety function distinct from circuit breakers. Although incapable of interrupting load or fault currents, its core purpose is establishing a visible air gap to safely isolate circuits, equipment, and bus sections during maintenance, commissioning, or system reconfiguration – ensuring personnel safety and operational flexibility.  

Core Functions & Operational Significance

I.Visible Air Gap Isolation:  

    Provides physical circuit separation verifiable at ground level. This unambiguous break is the primary safety assurance for personnel working on de-energized equipment (lines, transformers, breakers).  

II.Selective Circuit Segregation:  

    Enables isolation of individual feeders, transformers, or bus sections without de-energizing entire substations. Critical for:  

    – Equipment maintenance/repair  

    – Power flow rerouting (contingency management)  

    – Pre-energization testing of new assets  

III.Integrated Grounding Interface:  

    Often incorporates grounding blades. After main blade opening, grounding blades earth the isolated section, providing a complementary critical safety layer against accidental re-energization or induced voltages.  

Design & Technical Specifications

   Voltage Rating: Certified for 115 kV nominal voltage with defined dielectric withstand (BIL) and clearance margins.  

   Continuous Current Rating: Typically 1200A to 3000A+ at 115 kV.  

   Operating Mechanism:  

    – Gang-operated (standard): Motorized/manual ground-level drive with insulating linkages for simultaneous pole operation.  

    – Independent Pole Operation (IPO): Used where phase-segregated operation is justified.  

   Blade Architectures:  

    – Center-Break: Rotating blades pivot from central hinge.  

    – Double-Break: Horizontal/vertical motion creates two series breaks per phase.  

    – Vertical-Break: Gravity-assisted opening; preferred for compact substation layouts.  

   Auxiliary Arcing Contacts: Interrupt magnetizing/capacitive currents (e.g., transformer no-load current) without damaging main contacts.  

   Corona Suppression: Contoured contacts/hardware minimize RF noise and ionization at operating voltage.  

   Ice-Rated Operation: Meets IEC 62271-307 ice-breaking capacity requirements.  

Critical Safety Protocols

   Load Break Prohibition:  

    115 kV disconnect switches MUST NOT interrupt load current. Operation under load causes sustained arcs resulting in catastrophic equipment failure and personnel hazard. Operation permitted ONLY when:  

    – Upstream breaker has de-energized the circuit, OR  

    – Current is below arcing contact rating (verified by calculation/procedure).  

   Mandatory Interlocking:  

    Prevents:  

    – Operation with closed circuit breaker (load condition)  

    – Closing onto energized faulted circuits  

    – Grounding blade engagement with closed main blades  

   Dielectric Clearances:  

    Phase-to-phase/phase-to-ground clearances and insulator creepage distances comply with IEC 61936 for polluted environments.  

Typical 115 kV Applications

   Transformer primary/secondary isolation  

   Transmission line feeder isolation  

   Bus sectionalization (fault containment)  

   Circuit breaker bypass configurations  

   Shunt reactor/capacitor bank connections

Conclusion

The ABIMAT 115 kV disconnect switch is an indispensable asset in transmission infrastructure. Its value resides in establishing verifiable physical isolation – the foundational safety prerequisite for high-voltage work. By enabling selective de-energization and system reconfiguration, it ensures grid reliability while protecting personnel. Strict adherence to operational constraints (notably load-break prohibition) and robust interlocking are non-negotiable for safe deployment. Design evolution prioritizes enhanced environmental resilience, reduced maintenance, and integrated condition monitoring.