Manufacturer of Dropout fuse cutout, lightning surge Arrester, DISCONNECTING SWITCH, INSULATOR, WALL BUSING and INSLATING PROTECTION COVEr
email: info@abimat-electric.com        WeChat: 18368780285

PRODUCT LIST:

  • Standardized fuse cutout
  • ABFCO121 fuse cutout
  • ABFCO122 fuse cutout
  • ABFCO123 fuse cutout
  • ABFCO124 fuse cutout
  • ABFCO125 fuse cutout
  • 300A & 400A fuse cutout
  • Load break fuse cutout
  • Wind-resistant fuse cutout
  • Fuse Cutout Fittings – Brass Casting
  • Fuse Cutout Fittings – Stamped parts
  • Fuse Cutout Fittings – Fuse Links
  • Fuse Cutout Fittings – Other Accessories
  • Low voltage surge arrester
  • Distribution surge arrester
  • Polymer surge arrester
  • Anti pollution surge arrester
  • Pillar surge arrester
  • Station surge arrester
  • Capacitive surge arrester
  • Line type surge arrester
  • Dropout surge arrester
  • Arrester disconnection, time, online monitor
  • ABG1 disconnecting switch
  • ABG2 disconnecting switch
  • ABG3 disconnecting switch
  • ABG4 disconnecting switch
  • GW1 disconnecting switch
  • GW4 disconnecting switch
  • GW5 disconnecting switch
  • Low voltage disconnecting switch
  • Suspension insulator
  • Pin insulator
  • Post insulator
  • Cross arm insulator
  • Other insulator
  • Insulator hardware
  • Composite dry wall bushing
  • Porcelain wall bushing

Abimat Electric

  • ADDRESS: Deyu Road 5, Xiangyang Industry District, Yueqing City, Zhejiang Province, China
  • Email: info@abimat-electric.com
  • Wechat: 18368780285
WeChat Abimat Electric

Distribution Cutout: Critical Overhead Line Protection System

Operational Principle & Functional Design 

The ABIMAT distribution cutout serves as a fused isolation device in 15-38kV overhead distribution networks. This single-phase assembly integrates three core functions:  

Overcurrent protection via current-limiting fuse links  

Visible circuit isolation through gravity-operated drop-out mechanism  

Network sectionalization for fault confinement  

Fault interruption sequence:  

I.Downstream fault generates overcurrent (typically 5-20kA RMS)  

II.Fusible element melts per defined time-current characteristic (IEC 60282-1)  

III.Expulsion tube vents arc plasma through deionizing gas generation  

IV.Pivot mechanism releases fuse holder, rotating >45° from vertical  

V.Established air gap (>300mm) provides visual isolation confirmation  

Key Technical Parameters

CharacteristicStandard Requirement
Rated Voltage15kV/27kV/38kV (ANSI C37.42)
Continuous Current100A-300A
Symmetrical Interrupting Rating10kA (Type K fuse)
Basic Impulse Level110-150kV BIL
Fuse Speed ClassificationT (slow), K (fast)

 Primary Protective Functions  

Fault Containment  

Isolates transformer internal faults (winding shorts, bushing failures)  

Clears lateral line faults (animal/vegetation contact, lightning surges)  

Prevents upstream protection operation for downstream faults  

 

Transformer Protection  

Standard primary-side installation (≥95% of pole-mounted units)  

Coordination with secondary fuses (100:1 current ratio)  

Bay-O-Net® dual-element fuse links provide:  

  Instantaneous operation for internal faults (low-current protector link)  

  Time-delayed clearance for through-faults (high-current backup link)  

 

Network Sectionalizing  

Limits outage scope to 3-8 customers per device  

Reduces SAIDI (System Average Interruption Duration Index) by 25-40%  

Visual fault indication enables crew response within 30 minutes  

 Technological Evolution  

Conventional Designs  

– Porcelain insulators (Pollution Class III per IEC 60815)  

– Tin-plated copper contact systems  

– Mechanical drop-out indication  

 

Modern Advancements  

Polymer-housed units: UV-stabilized silicone rubber (IEC 62271-201)  

Electronic Cutouts (EFC):  

  – GSM/LoRaWAN remote fault reporting  

  ±1% accuracy fault current recording  

  – Adaptive coordination with reclosers  

Solid-material fuse links: Silver-graphite matrix prevents oxidation failure  

 Maintenance & Reliability Analysis  

Failure ModePrevalenceEngineering Solution
Moisture ingress42%Compression-molded silicone gaskets
Contact degradation28%Silver-nickel plating (100μm min)
Nuisance operation18%Solid-matrix fuse technology
Mechanism binding12%Ice-breaking pivot (IEC 60068-2-75)

Field Validation Protocol  

I. Thermographic inspection (ΔT ≤5°C between phases)  

II. Operating torque verification (≤50 N·m)  

III. Insulation resistance measurement (>1000 MΩ at 5kV DC)  

IV. Fuse continuity check (4-wire microhmmeter)  

 

 Industry Application Metrics  

Deployment density: 8-12 units per circuit mile  

Transformer protection: 63% reduction in replacement costs  

Fault clearance: 3-20 cycles (reclosers: 30+ cycles)  

Service life: 40+ years (porcelain), 25 years (polymer)  

Technology Evolution

– Motorized operation: SCADA-integrated actuators  

– Condition monitoring: Embedded temperature/position sensors  

– Hybrid switchgear: Vacuum interrupter integration for load-break capability  

– GIS variants: SF₆-insulated compact designs