FUSE CUTOUT - ABFCO124 SERIES
ABFCO124 series NCX fuse cutout is outdoor high voltage protection device. They are connected with the incoming feeder of 10kV~33kV distribution transformer or distribution lines. These are primarly used to protect transformers or lines from short circuits and overlords and switching currents.
The fuse cutout unit is composed of insulators supports and a fuse tube, static contacts is fixed on two sides of insulators supports and moving contact is installed on two ends of fuse tube. The interior of the fuse tube is the extinguishing tube, the exterior is made of phenolic compound paper tube or epoxy glass.
The parallel connector and NEMA brackets are available. The Abimat NCX fuse cutout is interchangeable with S&C, Chance, Cooper and ABB.

Fuse cutout details:
- Top hood: hot Galvanized Steel. Secure aligment to prevent side movement of hood, contacts or hooks.
- Spring: Stainless Steel, Spring provide sustained contact pressure.
- Upper contacts: silver to silver contacts, Tin to Tin contacts.
- Operating ring: Cast bronze/ brass tube casting and pull ring.
- Fuse tube: High-strength fiberglass fuse tube coated with ultra-violet inhibitor.
- Ferrule: Cast bronze/brass lower tube casting.
- Flipper: Stainless steel flipper, maintain tension of fuse link during closing and release tension when fuse link melted.
- Trunnion: Cast bronze/brass trunnion, silver to silver lower contacts with stainless steel backup Spring.
- Hinge: Cast bronze/brass hinge for corrosion resistance.
- Terminal: Brass parallel connector optional.
- Insulator: Bird proofed design one piece solid porcelain insulator or polymer insulator.
- Mounting Pin: Galvanized mounting pin for NEMA type mounting bracket.

For porcelain insulator, the porcelain body connects with hardware fitting by cement pouring, we use the special cement that has rapid solidification, high mechanical strength, low expansion coefficient and superior weather resistance.

For polymer insulator, the hardware fitting crimped onto fiberglass rod, material of housing and sheds manufacture of high-temperature Vulcanized Silicone Rubber, and the insulator moulded by one piece injection molding. It has good sealing performance and good performance of tracking and erosion resistance.

Our NCX fuse cutout adopts the design feature of double vent, exhaust downwards and upwards when fuse cutout interrupt. Prevent the intrusion of rainwater, avoid damage to the upper line by free gas, and this design can improve the interrupt capacity.

All ferrous parts processed by Stainless steel or hot dip galvanized, it’s zinc coating more than 80um, it has good corrosion resistance.

All copper casting part adopts bronze/brass, it has excellent mechanical strength and excellent conductivity. All contact parts be silver-plated, it adopts convex design on the contact surface, this design can reduce the contact resistance and ensure excellent conductivity. The high-strength memory cooper alloy sheets can ensure contact with lower contact smoothly and without any affecting when fuse drop out.

For Loadbreak type fuse cutout, its arc chamber made of special reinforced nylon material. It has good mechanical strength, anti-aging and flame retardant. suitable for use the area like high ultraviolet area, high altitude area, coastal area, etc.
FUSE CUTOUT TECHNICAL PARAMETERS:
TYPE | RATED VOLTAGE | RATED CURRENT | IMPULSE VOLTAGE (BIL) | POWER FREQUENCY VOLTAGE | CREEPAGE DISTANCE |
NCX-12/100A | 12kV | 100A | 110kV | 42kV | 220mm |
NCX-12/200A | 12kV | 200A | 110kV | 42kV | 220mm |
NCX-15/100A | 15kV | 100A | 125kV | 45kV | 320mm |
NCX-15/200A | 15kV | 200A | 125kV | 45kV | 320mm |
NCX-12F/100A | 12kV | 100A | 110kV | 42kV | 220mm |
NCX-12F/200A | 12kV | 200A | 110kV | 42kV | 220mm |
NCX-15F/100A | 15kV | 100A | 125kV | 45kV | 320mm |
NCX-15F/200A | 15kV | 200A | 125kV | 45kV | 320mm |
CONTACT US:
Leave Your Message:
TIPS:
When order,please indicate the detailed information as below listed:
1, Rated voltage and rated current .
2, Minimum creepage distance.
3, The material of insulator.
4, Please indicate whether parallel connector should be fitted with fuse cutout.
5, Please indicate whether NEMA bracket should be fitted with fuse cutout.
6, Please indicate whether arc-shortening rod should be fitted with fuse cutout.
EMAIL:info@abimat-electric.com