Manufacturer of Dropout fuse cutout, lightning surge Arrester, DISCONNECTING SWITCH, INSULATOR, WALL BUSING and INSLATING PROTECTION COVEr
email: info@abimat-electric.com        WeChat: 18368780285

PRODUCT LIST:

  • Standardized fuse cutout
  • ABFCO121 fuse cutout
  • ABFCO122 fuse cutout
  • ABFCO123 fuse cutout
  • ABFCO124 fuse cutout
  • ABFCO125 fuse cutout
  • 300A & 400A fuse cutout
  • Load break fuse cutout
  • Wind-resistant fuse cutout
  • Fuse Cutout Fittings – Brass Casting
  • Fuse Cutout Fittings – Stamped parts
  • Fuse Cutout Fittings – Fuse Links
  • Fuse Cutout Fittings – Other Accessories
  • Low voltage surge arrester
  • Distribution surge arrester
  • Polymer surge arrester
  • Anti pollution surge arrester
  • Pillar surge arrester
  • Station surge arrester
  • Capacitive surge arrester
  • Line type surge arrester
  • Dropout surge arrester
  • Arrester disconnection, time, online monitor
  • ABG1 disconnecting switch
  • ABG2 disconnecting switch
  • ABG3 disconnecting switch
  • ABG4 disconnecting switch
  • GW1 disconnecting switch
  • GW4 disconnecting switch
  • GW5 disconnecting switch
  • Low voltage disconnecting switch
  • Suspension insulator
  • Pin insulator
  • Post insulator
  • Cross arm insulator
  • Other insulator
  • Insulator hardware
  • Composite dry wall bushing
  • Porcelain wall bushing

Abimat Electric

  • ADDRESS: Deyu Road 5, Xiangyang Industry District, Yueqing City, Zhejiang Province, China
  • Email: info@abimat-electric.com
  • Wechat: 18368780285
WeChat Abimat Electric

Ground Disconnect Switch: Essential for Electrical Safety

  A Ground Disconnect Switch (GDS)—people also call it an Earthing Switch—is an important safety device in electrical systems. Its main job is to connect de-energized circuits to the ground securely. This keeps things safe during maintenance, repair or emergency work. It stops the circuits from getting energized by accident. It also protects workers from electric shock.
  Safety assurance is one of its key roles. It gives a visible ground connection. This connection makes sure isolated circuits stay at ground potential. It also helps with emergency protection. It works together with disconnectors. They quickly de-energize faulty sections and connect them to the ground. This lowers risks for people who handle emergencies. And it’s great for maintenance safety. It lets workers get close safely. It makes sure there’s no leftover voltage on the lines or equipment.
  Ground disconnect switches are built to be tough. They can handle strong fault currents. They also work well in harsh environments—like very hot or cold temperatures, high humidity and polluted areas. They often have mechanical interlocks with related disconnect switches. This interlock makes sure the disconnector opens first. Only then does the earthing switch close. This stops people from using the switches in a dangerous wrong way. You can operate them in two main ways. One is manual—using hand-operated parts. The other is motorized, which lets you control them from far away.
  These switches are a must-have in many places. You’ll find them in high-voltage substations and power distribution networks. They’re also used in industrial plants and commercial facilities. And they’re in renewable energy setups, like solar farms. These places need rapid shutdown systems—for example, as per NFPA 70 in the U.S.—to isolate DC sources.
  Their design, construction and use must follow strict standards. These standards are from international and regional bodies. Some examples are IEC, IEEE, ANSI/NEMA and GB standards. Following these standards makes sure the switches are reliable and safe to use. This is true when they’re used under the defined service conditions.
  To sum up, the Abimat ground disconnect switch is a basic part for electrical safety. Its tough design and fail-safe operation are very important. They help create a safe work environment. They also make sure electrical infrastructure and workers are protected overall.